Our laboratories at PRAKAB specialise primarily on the communication, installation and power cables up to 1kV, however, we are almost fully equipped for research and testing of most cable types.

Our analysis and research facilities are also available for your products or research projects. Several of our testing devices are accredited. 

It would be our pleasure to assist you with quality control on all levels, from the common input control up to the more challenging type tests.

Please do not hesitate to contact us for all your research and testing needs.

We perform these tests in our testing laboratories:

1. Nonelectric Tests

1. Measurement of Insulation Thickness

1. Measurement of Insulation Thickness

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 201: General tests - Measurement of insulation thickness

Standard:

ČSN EN 60811-201

Test Method:

Article 4

Test Equipment:

profile projector BATY
ccd camera
scanner Optit

Registration Nr.:

DOD 003
DOD 004
DOD 005

Range of Use:

Diameter max. 95 mm

More Less
2. Measurement of Thickness of Non Metallic Sheath

2. Measurement of Thickness of Non Metallic Sheath

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 202: General tests - Measurement of thickness of non metallic sheath

Standard:

ČSN EN 60811-201

Test Method:

Article 4

Test Equipment:

profile projector BATY ccd camera scanner Optit

Registration Nr.:

DOD 003

DOD 004

DOD 005

Range of Use:

Diameter max. 95 mm

More Less
3. Measurement of Overall Dimensions

3. Measurement of Overall Dimensions

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 203: General tests - Measurement of overall dimensions

Standard:

ČSN EN 60811-203

Test Method:

Article 4

Test Equipment:

Profile projector BATY
ccd camera
scanner Optit

Registration Nr.:

DOD 003

DOD 004

DOD 005

Range of Use:

Diameter max. 95 mm

More Less
4. Ageing in an Air Oven

4. Ageing in an Air Oven

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 401: Miscellaneous tests - Thermal ageing methods - Ageing in an air oven

Standard:

ČSN EN 60811-401

Test Method:

Article 4

Test Equipment:

Air ovens Heraeus

Registration Nr.:

TOD 002 -TOD 007

Range of Use:

Temperature max. 300°C

More Less
5. Water Absorption Tests -
Gravimetric Procedure

5. Water Absorption Tests - Gravimetric Procedure

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 402: Miscellaneous tests - Water absorption tests

Standard:

ČSN EN 60811-402

Test Method:

Article 4.4

Test Equipment:

Vacuum drying oven Vacucell
laboratory balance Sartorius 0.001

Registration Nr.:

TOD 009
TKD 018
EUD 006

Range of Use:

Temperature max. 260°C

More Less
6. Mineral Oil Immersion Tests For Sheaths

6. Mineral Oil Immersion Tests For Sheaths

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 404: Miscellaneous tests - Mineral oil immersion tests for sheaths

Standard:

ČSN EN 60811-404

Test Method:

Article 4

Test Equipment:

Air ovens Heraeus
oil Nr. 2 (IRM 902)

Registration Nr.:

TOD 002 -TOD 007

Range of Use:

Temperature max. 300°C

More Less
7. Thermal Stability Test for PVC Insulations and PVC Sheaths

7. Thermal Stability Test for PVC Insulations and PVC Sheaths

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 405: Miscellaneous tests - Thermal stability test for PVC insulations and PVC sheaths

Standard:

ČSN EN 60811-405

Test Method:

Article 4

Test Equipment:

Thermal bath Julabo
laboratory balance Sartorius 0.001
glass tubes + indicating paper

Registration Nr.:

TOD 001
HVD 001

Range of Use:

Temperature max. 250°C

More Less
8. Loss of Mass Test for Thermoplastic Insulations and Sheaths

8. Loss of Mass Test for Thermoplastic Insulations and Sheaths

Titel:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 409: Miscellaneous tests - Loss of mass test for thermoplastic insulations and sheaths

Standard:

ČSN EN 60811-405

Test Method:

Article 4

Test Equipment:

Thermal bath Julabo
laboratory balance Sartorius 0.001

Registration Nr.:

TOD 002 -TOD 007
HVD 001

Range of Use:

Temperature max. 300°C

More Less
9. Tests for Determining the Mechanical Properties of Insulating and Sheathing Compounds

9. Tests for Determining the Mechanical Properties of Insulating and Sheathing Compounds

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 501: Mechanical tests - Tests for determining the mechanical properties of insulating and sheathing compounds

Standard:

ČSN EN 60811-501

Test Method:

Article 4

Test Equipment:

Tensile test machine TIRA 3kN
punch, grooved punch, machine for preparing test pieces

Registration Nr.:

MTD 002

Range of Use:

max. 3 kN

More Less
10. Shrinkage Test For Insulations

10. Shrinkage Test For Insulations

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 502: Mechanical tests - Shrinkage test for insulations

Standard:

ČSN EN 60811-502

Test Method:

Article 4

Test Equipment:

Air ovens Heraeus horizontal support

Registration Nr.:

TOD 002 -TOD 007

Range of Use:

Temperature max. 300°C

More Less
11. Shrinkage Test for Sheaths

11. Shrinkage Test for Sheaths

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 503: Mechanical tests - Shrinkage test for sheaths

Standard:

ČSN EN 60811-503

Test Method:

Article 4

Test Equipment:

Air ovens Heraeus horizontal support

Registration Nr.:

TOD 002 -TOD 007

Range of Use:

Temperature max. 300°C

More Less
12. Bending Tests at Low Temperature for Insulation and Sheaths

12. Bending Tests at Low Temperature for Insulation and Sheaths

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 504: Mechanical tests - Bending tests at low temperature for insulation and sheaths

Standard:

ČSN EN 60811-504

Test Method:

Article 4

Test Equipment:

Cold bend test apparatus testing mandrel refrigerator -80°C

Registration Nr.:

TOA 011

Range of Use:

Temperature min. -80°C

More Less
13. Elongation at Low Temperature for Insulations and Sheaths

13. Elongation at Low Temperature for Insulations and Sheaths

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 505: Mechanical tests - Elongation at low temperature for insulations and sheaths

Standard:

ČSN EN 60811-505

Test Method:

Article 4

Test Equipment:

Prolongation test apparatus refrigerator -80°C

Registration Nr.:

TOA 011, MFA 003

Range of Use:

Temperature min. -80°C

More Less
14. Impact Test at Low Temperature for Insulations and Sheaths

14. Impact Test at Low Temperature for Insulations and Sheaths

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 506: Mechanical tests - Impact test at low temperature for insulations and sheaths

Standard:

ČSN EN 60811-506

Test Method:

Article 4

Test Equipment:

Impact test apparatus mass of the hammer 100 - 2000 g refrigerator -80°C

Registration Nr.:

TOA 011

Range of Use:

Temperature min. -80°C

More Less
15.  Mechanical Tests - Hot Set Test for Cross-linked Materials

15. Mechanical Tests - Hot Set Test for Cross-linked Materials

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 507: Mechanical tests - Hot set test for cross-linked materials

Standard:

ČSN EN 60811-507

Test Method:

Article 4

Test Equipment:

Air oven Heraeus grips load

Registration Nr.:

TOD 005

Range of Use:

Temperature max. 300°C

More Less
16. Pressure Test at High Temperature for Insulation and Sheath

16. Pressure Test at High Temperature for Insulation and Sheath

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 508: Mechanical test - Pressure test at high temperature for insulation and sheath

Standard:

ČSN EN 60811-508

Test Method:

Article 4.3 / 4.4

Test Equipment:

Air ovens Heraeus testing frame load

Registration Nr.:

TOD 002 -TOD 007

Range of use:

Temperature max. 300°C

More Less
17. Test for Resistance of Insulations and Sheaths to Cracking (Heat Shock Test)

17. Test for Resistance of Insulations and Sheaths to Cracking (Heat Shock Test)

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 509: Mechanical tests - Test for resistance of insulations and sheaths to cracking (heat shock test)

Standard:

ČSN EN 60811-509

Test Method:

Article 4.3 / 4.4

Test Equipment:

Air ovens Heraeus testing mandrel

Registration Nr.:

TOD 002 -TOD 007

Range of Use:

Temperature  max. 300°C

More Less
18. Wrapping Test after Thermal Ageing in Air

18. Wrapping Test after Thermal Ageing in Air

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 510: Mechanical tests - Methods specific to polyethylene and polypropylene compounds - Wrapping test after thermal ageing in air

Standard:

ČSN EN 60811-510

Test Method:

Article 4

Test Equipment:

Air ovens Heraeus bend test apparatus testing mandrel load

Registration Nr.:

TOD 002 - TOD 007

Range of use:

Temperature max. 300°C

More Less
19. Tensile Strength and Elongation at Break after Conditioning at Elevated Temperature

19. Tensile Strength and Elongation at Break after Conditioning at Elevated Temperature

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 512: Mechanical tests - Methods specific to polyethylene and polypropylene compounds - Tensile strength and elongation at break after conditioning at elevated temperature

Standard:

ČSN EN 60811-512

Test Method:

Article 4

Test Equipment:

Trhatensile test machine TIRA 3kN air ovens Heraeus

Registration Nr.:

MTD 002 TOD 002 - TOD 007

Range of Use:

Max. 3 kN

Temperature max. 300°C

More Less
20. Wrapping Test after Conditioning

20. Wrapping Test after Conditioning

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 513: Mechanical tests - Methods specific to polyethylene and polypropylene compounds - Wrapping test after conditioning

Standard:

ČSN EN 60811-513

Test Method:

Article 4

Test Equipment:

Air ovens Heraeus bend test apparatus testing mandrel load

Registration Nr.:

TOD 002 - TOD 007

Range of Use:

Temperature max. 300°C

More Less
21. Measurement of Carbon Black and/or Mineral Filler in Polyethylene Compounds

21. Measurement of Carbon Black and/or Mineral Filler in Polyethylene Compounds

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 605: Physical tests - Measurement of carbon black and/or mineral filler in polyethylene compounds

Standard:

ČSN EN 60811-605

Test Method:

Article 4.2 Method A – Measurement of carbon black and/or mineral filler content in polyethylene by direct combustion

Test Equipment:

Compact tube furnaces NABERTHERM
analytical balance
flowmeter

Register Nr.:

ZPD 007

Range of Use:

Temperature max. 1000°C

More Less
22. Methods for Determining the Density

22. Methods for Determining the Density

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 606: Physical tests - Methods for determining the density

Standard:

ČSN EN 60811-606

Test Method:

Article 4.4

Test Equipment:

Analytical balance
liquid bath

Registration Nr.:

HVD 014

More Less
23. Method A – Immersion Method

23. Method A – Immersion Method

Title:

Plastics - Methods for determining the density of non-cellular plastics - Part 1: Immersion method, liquid pyknometer method and titration method

Standard:

ČSN EN ISO 1183-1

Test Method:

Article 5.1

Test Equipment:

Analytical balance
liquid bath

Registration Nr.:

HVD 014

More Less
24. Shore A, D

24. Shore A, D

Title:

Plastics and ebonite - Determination of indentation hardness by means of a durometer (Shore hardness)

Standard:

ČSN EN ISO 868

Test Method:

Article 8

Test Equipment:

digital Shorehardness Tester HPE II Bareiss

Registration Nr.:

SOD 035
SOD 036

More Less
25. Shore A, D

25. Shore A, D

Title:

Rubber, vulcanized or thermoplastic - Determination of indentation hardness - Part 1: Durometer method (Shore hardness)

Standard:

ČSN ISO 7619-1

Test Method:

Article 7

Test Equipment:

digital Shorehardness Tester HPE II Bareiss

Registration Nr.:

SOD 035
SOD 036

More Less
26. Measurement of Shore D Hardness of PE Sheath

26. Measurement of Shore D Hardness of PE Sheath

Title:

Electric cables - Additional test methods

Standard:

ČSN 34 7010-82
HD605.S2:2008

Test Method:

Article 2.2.1
Method A / B

Test Equipment:

Digital Shorehardness Tester HPE II Bareiss

Registration Nr.:

SOD 035
SOD 036

More Less
27. Determination of Tear Resistance of the Protective Sheath

27. Determination of Tear Resistance of the Protective Sheath

Title:

Electric cables - Additional test methods

Standard:

ČSN 34 7010-82
HD605.S2:2008

Test Method:

Article 2.2.2
Method 1/ Method 2

Test Equipment:

Tensile test machine TIRA 3kN
punch, machine for preparing test pieces

Registration Nr.:

MTD 002

Range of Use:

max. 3 kN

More Less
28. Tensile Test on Metallic Components

28. Tensile Test on Metallic Components

Title:

Electric cables - Additional test methods

Standard:

ČSN 34 7010-82
HD605.S2:2008

Test Method:

Article 2.3.1

Test Equipment:

Tensile test machine TIRA 3kN
tensile test machine ZD 10/90 100kN

Registration Nr.:

MTD 002
MTA 302

Range of Use:

max. 100 kN

More Less
29. 5.4.2 Resistance to water penetration

29. 5.4.2 Resistance to water penetration

Title:

Low-frequency cables with polyolefin insulation and moisture barrier polyolefin sheath

Standard:

ČSN EN 60708-1

Test Method:

ČSN EN 60794-1-2 ed. 2
Method F5: water penatration
F5A/B

Test Equipment:

Test device according to Figure 29

Range of Use:

Diameter max. 100 mm

More Less
30. Testing of Adherence of Insulation on Messenger Conductor

30. Testing of Adherence of Insulation on Messenger Conductor

Title:

Overhead distribution cables of rated voltage U0/U (Um): 0,6/1 (1,2) kV - Part 2: Additional test methods

Standard:

ČSN 34 7614-2

Test Method:

Article 2.2.2 Method 2

Test Equipment:

Tensile test machine ZD 10/90 100kN
Test device according to Figure 2.2.2.1

Registration Nr.:

MTA 302

Range of Use:

max. 100 kN
cross-section 16,25,35,50,70,95,120, 150 mm2

More Less
31. Testing of Adherence of Insulation on Conductor

31. Testing of Adherence of Insulation on Conductor

Title:

Overhead distribution cables of rated voltage U0/U (Um): 0,6/1 (1,2) kV - Part 2: Additional test methods

Standard:

ČSN 34 7614-2

Test Method:

Article 2.2.3 Method 3

Test Equipment:

Tensile test machine ZD 10/90 100kN
Test device according to Figure 2.2.3.1

Registration Nr.:

MTA 302

Range of Use:

max. 100 kN

More Less
32. Testing of Adherence of Insulation on Conductor

32. Testing of Adherence of Insulation on Conductor

Title:

Overhead distribution cables of rated voltage U0/U (Um): 0,6/1 (1,2) kV - Part 2: Additional test methods

Standard:

ČSN 34 7614-2

Test Method:

Article 2.2.4 Method 4

Test Equipment:

Tensile test machine ZD 10/90 100kN
Test device according to Figure 2.2.4.1

Registration Nr.:

MTA 302

Range of Use:

max. 100 kN
cross-section 35,50,70,95 mm2

More Less
33. Testing of Adherence of Insulation on Messenger Conductor

33. Testing of Adherence of Insulation on Messenger Conductor

Title:

Overhead distribution cables of rated voltage U0/U (Um): 0,6/1 (1,2) kV - Part 2: Additional test methods

Standard:

ČSN 34 7614-2

Test Method:

Article 2.2.5 Method 5

Test Equipment:

Tensile test machine ZD 10/90 100kN
Test device according to Figure 2.2.5.1

Registration Nr.:

MTA 302

Range of Use:

max. 100 kN
cross-section 35,50,70,95 mm2

More Less
34. Adhesion Between Core Insulation of XLPE insulated Conductors and Cast Resin

34. Adhesion Between Core Insulation of XLPE insulated Conductors and Cast Resin

Title:

Distribution cables of rated voltage 0,6/1 kV - Section 5G: Cables with (type 5G-1) or without (type 5G-2) concentric conductor

Standard:

ČSN 34 7659-5G

Test Method:

Clause 7

Test Equipment:

Tensile test machine TIRA 3kN
peeling device
silicon mould

Registration Nr.:

MTD 002

Range of Use:

max. 3 kN

More Less

2. Electric Tests

35. Electrical Resistance - Conductor

35. Electrical Resistance - Conductor

Title:

Electric cables - Additional test methods

Standard:

ČSN 34 7010-82

Test Method:

Article 3.1.1

Test Equipment:

High-precision automatic inspection and test unit for electrical resistence testing Burster 2304
200 µΩ to 20 kΩ

Range of Use:

max. 630 mm2

More Less
36. Electrical Resistence - Conductor

36. Electrical Resistence - Conductor

Title:

Conductors of insulated cables

Standard:

ČSN EN 60228

Test Method:

Annex A

Test Equipment:

High-precision automatic inspection and test unit for electrical resistence testing Burster 2304
200 µΩ to 20 kΩ

Registration Nr.:

ERD 030
ERD 001
ERD 029
ERD 005
ERD 004

Range of Use:

max. 630 mm2

More Less
37. Electrical d.c. Resistance of Conductor

37. Electrical d.c. Resistance of Conductor

Title:

Electrical test methods for low voltage energy cables

Standard:

ČSN EN 50395

Test Method:

Article 5

Test Equipment:

High-precision automatic inspection and test unit for electrical resistence testing Burster 2304
200 µΩ bis 20 kΩ
200 µΩ bis 20 kΩ

Range of Use:

max. 630 mm2

More Less
38. Electrical Resistance of Conductors

38. Electrical Resistance of Conductors

Title:

Low-frequency cables and wires with PVC insulation and PVC sheath – Part 1: General test and measuring methods (IEC 60189)

Standard:

IEC 60189

Test Method:

Article 8.1

Test Equipment:

High-precision automatic inspection and test unit for electrical resistence testing Burster 2304
200 µΩ to 20 kΩ

Range of Use:

max. 630 mm2

More Less
39. Voltage Tests on Complete Cable

39. Voltage Tests on Complete Cable

Title:

Voltage tests on complete cable

Standard:

ČSN 34 7010-82

Test Method:

Article 3.2.1

Test Equipment:

High voltage device
max. 35 kV AC
max. 12.5 kV DC
max. 300 V DC

Registration Nr.:

ZEA 003

Range of Use:

Cables up to 1 kV

More Less
40. Voltage Tests on Cores

40. Voltage Tests on Cores

Title:

Electric cables - Additional test methods

Standard:

ČSN 34 7010-82
HD605.S2:2008

Test Method:

Article 3.2.2

Test Equipment:

High voltage device
max. 35 kV AC
max. 12.5 kV DC
max. 300 V DC

Registration Nr.:

ZEA 001
EUD005
EUD 001

Range of Use:

Cables up to 1 kV

More Less
41. Voltage Tests on Oversheath

41. Voltage Tests on Oversheath

Title:

Electric cables - Additional test methods

Standard:

ČSN 34 7010-82
HD605.S1

Test Method:

Article 3.2.3

Test Equipment:

High voltage device
max. 35 kV AC
max. 12.5 kV DC
max. 300 V DC

Registration Nr.:

ZEA 003

Range of Use:

cables up to 1 kV

More Less
42. Check for the Absence of Faults in Insulation

42. Check for the Absence of Faults in Insulation

Title:

Electrical test methods for low voltage energy cables

Standard:

ČSN EN 50395

Test Method:

Article 10

Test Equipment:

VN High voltage device
max. 35 kV AC
max. 12.5 kV DC
max. 300 V DC

Registration Nr.:

ZEA 003

Range of Use:

Cables up to 1 kV

More Less
43. Voltage Test on Completed Cable

43. Voltage Test on Completed Cable

Title:

Electrical test methods for low voltage energy cables

Standard:

ČSN EN 50395

Test Method:

Article 6

Test Equipment:

High voltage device
max. 35 kV AC
max. 12.5 kV DC
max. 300 V DC

Registration Nr.:

ZEA 003

Range of Use:

Cables up to 1 kV

More Less
44. Voltage Test on Cores in Water

44. Voltage Test on Cores in Water

Title:

ElElectrical test methods for low voltage energy cables

Standard:

ČSN EN 50395

Test Method:

Article 7

Test Equipment:

High voltage device
max. 35 kV AC
max. 12.5 kV DC
max. 300 V DC

Registration Nr.:

ZEA 003

Range of Use:

Cables up to 1 kV

More Less
45. Dielectric Strength

45. Dielectric Strength

Title:

Low-frequency cables and wires with PVC insulation and PVC sheath – Part 1: General test and measuring methods

Standard:

IEC 60189

Test Method:

Article 8.2

Test Equipment:

Insulation resistance tester Megger
High voltage device Hipotronic

Registration Nr.:

ERD 027
EUD 001

Range of Use:

Megger max. 5kV DC
Hypotronic max. 3.75 AC

More Less
46. Insulation Resistance Test on Insulated Cores

46. Insulation Resistance Test on Insulated Cores

Title:

Electric cables - Additional test methods

Standard:

ČSN 34 7010-82

Test Method:

Article 3.3.2

Test Equipment:

Insulation resistance tester Megger

Registration Nr.:

ERD 032

Range of Use:

Cables up to 1 kV

More Less
47. Insulation Resistance Test on Screened or Armoured Complete Cable

47. Insulation Resistance Test on Screened or Armoured Complete Cable

Title:

Electric cables - Additional test methods

Standard:

ČSN 34 7010-82

Test Method:

Article 3.3.3

Test Equipment:

Insulation resistance tester Megger

Range of Use:

Cables up to 1 kV

More Less
48. Insulation Resistance Test on Unscreened or Unarmoured Complete Cable

48. Insulation Resistance Test on Unscreened or Unarmoured Complete Cable

Title:

Electric cables - Additional test methods

Standard:

ČSN 34 7010-82

Test Method:

Article 3.3.4

Test Equipment:

Insulation resistance tester Megger

Range of Use:

Cables up to 1 kV

More Less
49. Oversheath Resistance Test on Screened or Armoured Complete Cable

49. Oversheath Resistance Test on Screened or Armoured Complete Cable

Title:

Electric cables - Additional test methods

Standard:

ČSN 34 7010-82

Test Method:

Article 8

Test Equipment:

Insulation resistance tester Megger

Range of Use:

Cables up to 1 kV

More Less
50. Insulation Resistance Test

50. Insulation Resistance Test

Title:

Electrical test methods for low voltage energy cables

Standard:

ČSN EN 50395

Test Method:

Article 8.3

Test Equipment:

Insulation resistance tester Megger

Range of Use:

Cables up to 1 kV

More Less
51. Insulation Resistance

51. Insulation Resistance

Title:

Low-frequency cables and wires with PVC insulation and PVC sheath – Part 1: General test and measuring methods

Standard:

IEC 60189

Test Method:

Article 3.4

Test Equipment:

Insulation resistance tester Megger

Range of Use:

Cables up to 1 kV

More Less
52. Surface Resistance of the Cable Oversheath

52. Surface Resistance of the Cable Oversheath

Title:

Electric cables - Additional test methods

Standard:

ČSN 34 7010-82
HD605.S2:2008

Test Method:

Article 11

Test Equipment:

Insulation resistance tester Megger

Registration Nr.:

ERD 032

Range of Use:

max. 5kV DC

More Less
53. Surface Resistance of Sheath

53. Surface Resistance of Sheath

Title:

Electrical test methods for low voltage energy cables

Standard:

ČSN EN 50395

Test Method:

Article 3.2.2.1

Test Equipment:

Insulation resistance tester Megger

Range of Use:

max. 5kV DC

More Less
54. DC Voltage Test on Insulation

54. DC Voltage Test on Insulation

Title:

Electric cables - Additional test methods

Standard:

ČSN 34 7010-82

Test Method:

Article 9

Test Equipment:

High voltage device max. 12.5 kV DC water bath

Registration Nr.:

ZEA 003

Range of Use:

max. 12.5 kV DC

More Less
55. Long Term Resistance of Insulation to d.c.

55. Long Term Resistance of Insulation to d.c.

Title:

Electrical test methods for low voltage energy cables

Standard:

ČSN EN 50395

Test Method:

Article 9

Test Equipment:

High voltage device max. 300 V DC water bath

Registration Nr.:

ZEA 003

Range of Use:

max. 300 V DC

More Less
56. Measurement of Electrical Resistence of Conductor, Mutual Capacitance and Capacitance Unbalance

56. Measurement of Electrical Resistence of Conductor, Mutual Capacitance and Capacitance Unbalance

Title:

Low-frequency cables and wires with PVC insulation and PVC sheath – Part 1: General test and measuring methods

Standard:

IEC 60189-1

Test Equipment:

Automatic telephone cable tester AESA

Registration Nr.:

EOD 006
EOD 014

Range of Use:

max. diameter of conductor 1.0 mm

More Less
57. Measurement of HF Parameters (up to 10 MHz)

57. Measurement of HF Parameters (up to 10 MHz)

Title:

Multi-element metallic cables used in analogue and digital communication and control - Part 1: Generic specification

Standard:

ČSN EN 50288-1 ed.2

Test Equipment:

HP Analyzátor

Range of Use:

max. 10 MHz

More Less
58. Measurement of Reduction Factor

58. Measurement of Reduction Factor

Title:

Testing of cables, wires and flexible cords - reduction factor

Standard:

DIN VDE 0472
Teil 507

Test Method:

According to standard

Registration Nr.:

ZEA 004

More Less
59. Water Absorption Tests - Electrical Procedure

59. Water Absorption Tests - Electrical Procedure

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 402: Miscellaneous tests - Water absorption tests

Standard:

ČSN EN 60811-402

Test Method:

Article 4.3

Test Equipment:

High voltage device

water bath

Registration Nr:

TKD 018
EUD 006

Range of Use:

Temperature max. 99°C
AC max. 35 kV
DC max. 12,5 kV

More Less

3. Tests under Fire Conditions

60. Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables - Apparatus

60. Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables - Apparatus

Title:

Tests on electric and optical fibre cables under fire conditions - Part 3-10: Test for vertical flame spread of vertically-mounted bunched wires or cables - Apparatus

Standard:

ČSN EN 60332-3-10

Test Equipment:

according to standard

Registration Nr.:

ZPD 004

Range of Use:

standard / wide - ladder
1 or 2 burners

More Less
61. Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables - Category A F/R

61. Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables - Category A F/R

Title:

Tests on electric and optical fibre cables under fire conditions - Part 3-21: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category A F/R

Standard:

ČSN EN 60332-3-21

Test Equipment:

According to standard

Registration Nr.:

ZPD 004

More Less
62. Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables - Category A

62. Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables - Category A

Title:

Tests on electric and optical fibre cables under fire conditions - Part 3-22: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category A

Standard:

ČSN EN 60332-3-22

Test Equipment:

According to standard

Registration Nr.:

ZPD 004

More Less
63. Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables - Category B

63. Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables - Category B

Title:

Tests on electric and optical fibre cables under fire conditions - Part 3-23: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category B

Standard:

ČSN EN 60332-3-23

Test Equipment:

According to standard

Registration Nr.:

ZPD 004

More Less
64. Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables - Category C

64. Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables - Category C

Title:

Tests on electric and optical fibre cables under fire conditions - Part 3-24: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category C

Standard:

ČSN EN 60332-3-24

Test Equipment:

According to standard

Registration Nr.:

ZPD 004

Range of Use:

According to DIN VDE too

More Less
65. Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables - Category D

65. Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables - Category D

Title:

Tests on electric and optical fibre cables under fire conditions - Part 3-25: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category D

Standard:

ČSN EN 60332-3-25

Test Equipment:

According to standard

Registration Nr.:

ZPD 004

More Less
66. Tests on Gases Evolved During Combustion of Materials from Cables - Apparatus

66. Tests on Gases Evolved During Combustion of Materials from Cables - Apparatus

Title:

Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 1: Apparatus

Standard:

ČSN EN 50267-1

Test Equipment:

According to standard

Registration Nr.:

ZPD 007

Range of Use:

max. temperature 1000°C

More Less
67. Determination of the Amount of Halogen Acid Gas

67. Determination of the Amount of Halogen Acid Gas

Title:

Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-1: Procedures - Determination of the amount of halogen acid gas

Standard:

ČSN EN 50267-2-1

Test Equipment:

According to standard

Registration Nr.:

ZPD 007

Range of Use:

For halogen materials

More Less
68. Determination of Degree of Acidity of Gases for Materials by Measuring pH and Conductivity

68. Determination of Degree of Acidity of Gases for Materials by Measuring pH and Conductivity

Title:

Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-2: Procedures - Determination of degree of acidity of gases for materials by measuring pH and conductivity

Standard:

ČSN EN 50267-2-2

Test Equipment:

According to standard

Registration Nr.:

ZPD 007

More Less
69. Determination of Degree of Acidity of Gases for Cables by Determination of the Weighted Average of pH and Conductivity

69. Determination of Degree of Acidity of Gases for Cables by Determination of the Weighted Average of pH and Conductivity

Title:

Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-3: Procedures - Determination of degree of acidity of gases for cables by determination of the weighted average of pH and conductivity

Standard:

ČSN EN 50267-2-3

Test Equipment:

According to standard

Registration Nr.:

ZPD 007

More Less
70. Circuit integrity - Cables for Use in Emergency Circuits

70. Circuit integrity - Cables for Use in Emergency Circuits

Title:

Method of test for resistance to fire of unprotected small cables for use in emergency circuits

Standard:

ČSN EN 50200 ed.2

Test Equipment:

According to standard

Registration Nr.:

ZPD 005

Range of Use:

Cables up to 1 kV

More Less
71. Circuit integrity - Cables for Use in Emergency Circuits

71. Circuit integrity - Cables for Use in Emergency Circuits

Title:

Method of test for resistance to fire of larger unprotected power and control cables for use in emergency circuits

Standard:

ČSN EN 50362

Test Equipment:

According to standard

Registration Nr.:

ZPD 005

Range of Use:

Cables up to 1 kV

More Less
72. Measurement of Smoke Density - Apparatus

72. Measurement of Smoke Density - Apparatus

Title:

Measurement of smoke density of cables burning under defined conditions - Part 1: Apparatus

Standard:

ČSN EN 61034-1

Test Equipment:

According to standard

Registration Nr.:

ZPD 006

More Less
73. Measurement of Smoke Density

73. Measurement of Smoke Density

Title:

Measurement of smoke density of cables burning under defined conditions - Part 2: Test procedure and requirements

Standard:

ČSN EN 61034-2

Test Equipment:

According to standard

Registration Nr.:

ZPD 006

More Less
74. Circuit integrity - Apparatus

74. Circuit integrity - Apparatus

Title:

Tests for electric cables under fire conditions - Circuit integrity - Part 11: Apparatus - Fire alone at a flame temperature of at least 750 °C

Standard:

ČSN IEC 60331-11

Test Equipment:

According to standard

Registration Nr.:

ZPD 005

Range of Use:

Cables up to 1 kV

More Less
75. Circuit integrity - Cables of Rated Voltage 0,6/1kV

75. Circuit integrity - Cables of Rated Voltage 0,6/1kV

Title:

Tests for electric cables under fire conditions - Circuit integrity - Part 21: Procedures and requirements - Cables of rated voltage up to and including 0,6/1,0 kV

Standard:

ČSN IEC 60331-21

Test Equipment:

According to standard

Registration Nr.:

ZPD 005

Range of Use:

Cables up to 1 kV

More Less
76. Circuit Integrity - Electric Data Cables

76. Circuit Integrity - Electric Data Cables

Title:

Tests for electric cables under fire conditions - Circuit integrity - Part 23: Procedures and requirements - Electric data cables

Standard:

ČSN IEC 60331-23

Test Equipment:

According to standard

Registration Nr.:

ZPD 005

Range of Use:

Cables up to 1 kV

More Less
77. Heat Release and Smoke Production Measurement on Cables During Flame Spread Test

77. Heat Release and Smoke Production Measurement on Cables During Flame Spread Test

Title:

Common test methods for cables under fire conditions - Heat release and smoke production measurement on cables during flame spread test - Test Apparatus, procedures, results

Standard:

ČSN EN 50399-1

Test Equipment:

According to standard

Registration Nr.:

ZPD 009

Range of Use:

Only electric cables

More Less
78. Determination of Burning Behaviour by Oxygen Index

78. Determination of Burning Behaviour by Oxygen Index

Title:

Plastics - Determination of burning behaviour by oxygen index - Part 1: Guidance

Standard:

ČSN EN ISO 4589-1

Test Equipment:

According to standard

Registration Nr.:

ZPD 010

Range of Use:

min. thickness 3 mm

More Less
79. Determination of Burning Behaviour by Oxygen Index

79. Determination of Burning Behaviour by Oxygen Index

Title:

Plastics - Determination of burning behaviour by oxygen index - Part 2: Ambient-temperature test

Standard:

ČSN EN ISO 4589-2

Test Equipment:

According to standard

Registration Nr.:

ZPD 010

Range of Use:

min. tloušťka 3 mm

More Less
80. Test for Vertical Flame Propagation for a Single Insulated Wire or Cable - Apparatus

80. Test for Vertical Flame Propagation for a Single Insulated Wire or Cable - Apparatus

Title:

Tests on electric and optical fibre cables under fire conditions - Part 1-1: Test for vertical flame propagation for a single insulated wire or cable - Apparatus

Standard:

ČSN EN 60332-1-1

Test Equipment:

According to standard

Registration Nr.:

ZPD 008

More Less
81. Test for Vertical Flame Propagation for a Single Insulated Wire or Cable - Procedure for 1 kW Pre-mixed Flame

81. Test for Vertical Flame Propagation for a Single Insulated Wire or Cable - Procedure for 1 kW Pre-mixed Flame

Title:

Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame

Standard:

ČSN EN 60332-1-2

Test Equipment:

According to standard

Registration Nr.:

ZPD 008

More Less
82.  Test for Vertical fFame Propagation for a Single Insulated Wire or Cable - Procedure for Determination of Flaming Droplets/Particles

82. Test for Vertical fFame Propagation for a Single Insulated Wire or Cable - Procedure for Determination of Flaming Droplets/Particles

Title:

Tests on electric and optical fibre cables under fire conditions - Part 1-3: Test for vertical flame propagation for a single insulated wire or cable - Procedure for determination of flaming droplets/particles

Standard:

ČSN EN 60332-1-3

Test Equipment:

According to standard

Registration Nr.:

ZPD 008

More Less
83. Test for Vertical Flame Propagation for a Single Insulated Wire or Cable - Apparatus

83. Test for Vertical Flame Propagation for a Single Insulated Wire or Cable - Apparatus

Title:

Tests on electric and optical fibre cables under fire conditions - Part 2-1: Test for vertical flame propagation for a single small insulated wire or cable - Apparatus

Standard:

ČSN EN 60332-2-1

Test Equipment:

According to standard

Registration Nr.:

ZPD 008

More Less
84. Test for Vertical Flame Propagation for a Single Insulated Wire or Cable - Procedure for Diffusion Flame

84. Test for Vertical Flame Propagation for a Single Insulated Wire or Cable - Procedure for Diffusion Flame

Title:

Tests on electric and optical fibre cables under fire conditions - Part 2-2: Test for vertical flame propagation for a single small insulated wire or cable - Procedure for diffusion flame

Standard:

ČSN EN 60332-2-2

Test Equipment:

According to standard

Registration Nr.:

ZPD 008

Range of Use:

for cables with a diameter up to 0.5 mm

More Less

We hold many product certificates and other documents proving our competencies and the highest product quality. The following links will refer you to the web pages of our prominent partners in the area of product certification, conformity evaluation, product classification and fire resistance tests.