• LANGUAGE:
  • english
  • čeština

Testing & Development Centre

Our laboratories at PRAKAB specialise primarily on the communication, installation and power cables up to 1kV, however, we are almost fully equipped for research and testing of most cable types.

Our analysis and research facilities are also available for your products or research projects. Several of our testing devices are accredited. 

It would be our pleasure to assist you with quality control on all levels, from the common input control up to the more challenging type tests.

Please do not hesitate to contact us for all your research and testing needs.

We perform these tests in our testing laboratories:

1. Nonelectric Tests

1. Measurement of Insulation Thickness

1. Measurement of Insulation Thickness

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 201: General tests - Measurement of insulation thickness

Standard:

EN 60811-201

Test Method:

Article 4

Test Equipment:

profile projector BATY
ccd camera
scanner Optit

Range of Use:

Diameter max. 95 mm

More Less
2. Measurement of Thickness of Non Metallic Sheath

2. Measurement of Thickness of Non Metallic Sheath

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 202: General tests - Measurement of thickness of non metallic sheath

Standard:

EN 60811-202

Test Method:

Article 4

Test Equipment:

profile projector BATY ccd camera scanner Optit

Range of Use:

Diameter max. 95 mm

More Less
3. Measurement of Overall Dimensions

3. Measurement of Overall Dimensions

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 203: General tests - Measurement of overall dimensions

Standard:

EN 60811-203

Test Method:

Article 4

Test Equipment:

Profile projector BATY
ccd camera
scanner Optit

Range of Use:

Diameter max. 95 mm

More Less
4. Ageing in an Air Oven

4. Ageing in an Air Oven

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 401: Miscellaneous tests - Thermal ageing methods - Ageing in an air oven

Standard:

EN 60811-401

Test Method:

Article 4

Test Equipment:

Air ovens

Range of Use:

Temperature max. 300°C

More Less
5. Water Absorption Tests -
Gravimetric Procedure

5. Water Absorption Tests - Gravimetric Procedure

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 402: Miscellaneous tests - Water absorption tests

Standard:

EN 60811-402

Test Method:

Article 4.4

Test Equipment:

Vacuum drying oven Vacucell
laboratory balance

Range of Use:

Temperature max. 260°C

More Less
6. Mineral Oil Immersion Tests For Sheaths

6. Mineral Oil Immersion Tests For Sheaths

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 404: Miscellaneous tests - Mineral oil immersion tests for sheaths

Standard:

EN 60811-404

Test Method:

Article 4

Test Equipment:

Air ovens
oil Nr. 2 (IRM 902)

Range of Use:

Temperature max. 300°C

More Less
7. Thermal Stability Test for PVC Insulations and PVC Sheaths

7. Thermal Stability Test for PVC Insulations and PVC Sheaths

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 405: Miscellaneous tests - Thermal stability test for PVC insulations and PVC sheaths

Standard:

EN 60811-405

Test Method:

Article 4

Test Equipment:

Thermal bath Julabo
laboratory balance
glass tubes + indicating paper

Range of Use:

Temperature max. 250°C

More Less
8. Loss of Mass Test for Thermoplastic Insulations and Sheaths

8. Loss of Mass Test for Thermoplastic Insulations and Sheaths

Titel:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 409: Miscellaneous tests - Loss of mass test for thermoplastic insulations and sheaths

Standard:

EN 60811-409

Test Method:

Article 4

Test Equipment:

air oven
laboratory balance

Range of Use:

Temperature max. 300°C

More Less
9. Tests for Determining the Mechanical Properties of Insulating and Sheathing Compounds

9. Tests for Determining the Mechanical Properties of Insulating and Sheathing Compounds

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 501: Mechanical tests - Tests for determining the mechanical properties of insulating and sheathing compounds

Standard:

EN 60811-501

Test Method:

Article 4

Test Equipment:

Tensile test machine TIRA 3kN

punch

machine for preparing test pieces

Range of Use:

max. 3 kN

More Less
10. Shrinkage Test For Insulations

10. Shrinkage Test For Insulations

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 502: Mechanical tests - Shrinkage test for insulations

Standard:

EN 60811-502

Test Method:

Article 4

Test Equipment:

air ovens

horizontal support

Range of Use:

Temperature max. 300°C

More Less
11. Shrinkage Test for Sheaths

11. Shrinkage Test for Sheaths

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 503: Mechanical tests - Shrinkage test for sheaths

Standard:

EN 60811-503

Test Method:

Article 4

Test Equipment:

air ovens

horizontal support

Range of Use:

Temperature max. 300°C

More Less
12. Bending Tests at Low Temperature for Insulation and Sheaths

12. Bending Tests at Low Temperature for Insulation and Sheaths

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 504: Mechanical tests - Bending tests at low temperature for insulation and sheaths

Standard:

EN 60811-504

Test Method:

Article 4

Test Equipment:

cold bend test apparatus

testing mandrel

refrigerator -80°C

Range of Use:

Temperature min. -80°C

More Less
13. Elongation at Low Temperature for Insulations and Sheaths

13. Elongation at Low Temperature for Insulations and Sheaths

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 505: Mechanical tests - Elongation at low temperature for insulations and sheaths

Standard:

EN 60811-505

Test Method:

Article 4

Test Equipment:

prolongation test apparatus

refrigerator -80°C

Range of Use:

Temperature min. -80°C

More Less
14. Impact Test at Low Temperature for Insulations and Sheaths

14. Impact Test at Low Temperature for Insulations and Sheaths

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 506: Mechanical tests - Impact test at low temperature for insulations and sheaths

Standard:

EN 60811-506

Test Method:

Article 4

Test Equipment:

impact test apparatus

mass of the hammer 100 - 2000 g

refrigerator -80°C

Range of Use:

Temperature min. -80°C

More Less
15.  Mechanical Tests - Hot Set Test for Cross-linked Materials

15. Mechanical Tests - Hot Set Test for Cross-linked Materials

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 507: Mechanical tests - Hot set test for cross-linked materials

Standard:

EN 60811-507

Test Method:

Article 4

Test Equipment:

air oven

grips

load

Range of Use:

Temperature max. 300°C

More Less
16. Pressure Test at High Temperature for Insulation and Sheath

16. Pressure Test at High Temperature for Insulation and Sheath

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 508: Mechanical test - Pressure test at high temperature for insulation and sheath

Standard:

EN 60811-508

Test Method:

Article 4.3 / 4.4

Test Equipment:

air ovens

testing frame load

Range of use:

Temperature max. 300°C

More Less
17. Test for Resistance of Insulations and Sheaths to Cracking (Heat Shock Test)

17. Test for Resistance of Insulations and Sheaths to Cracking (Heat Shock Test)

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 509: Mechanical tests - Test for resistance of insulations and sheaths to cracking (heat shock test)

Standard:

EN 60811-509

Test Method:

Article 4.3 / 4.4

Test Equipment:

air oven

testing mandrel

Range of Use:

Temperature  max. 300°C

More Less
18. Wrapping Test after Thermal Ageing in Air

18. Wrapping Test after Thermal Ageing in Air

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 510: Mechanical tests - Methods specific to polyethylene and polypropylene compounds - Wrapping test after thermal ageing in air

Standard:

EN 60811-510

Test Method:

Article 4

Test Equipment:

air oven

bend test apparatus

testing mandrel

load

Range of use:

Temperature max. 300°C

More Less
19. Tensile Strength and Elongation at Break after Conditioning at Elevated Temperature

19. Tensile Strength and Elongation at Break after Conditioning at Elevated Temperature

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 512: Mechanical tests - Methods specific to polyethylene and polypropylene compounds - Tensile strength and elongation at break after conditioning at elevated temperature

Standard:

EN 60811-512

Test Method:

Article 4

Test Equipment:

tensile test machine TIRA 3kN

air oven

Range of Use:

Max. 3 kN

Temperature max. 300°C

More Less
20. Wrapping Test after Conditioning

20. Wrapping Test after Conditioning

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 513: Mechanical tests - Methods specific to polyethylene and polypropylene compounds - Wrapping test after conditioning

Standard:

EN 60811-513

Test Method:

Article 4

Test Equipment:

air oven

bend test apparatus

testing mandrel

load

Range of Use:

Temperature max. 300°C

More Less
21. Measurement of carbon black and/or mineral filler content in polyethylene by direct combustion

21. Measurement of carbon black and/or mineral filler content in polyethylene by direct combustion

For further information, please contact our laboratory.

More Less
22. Methods for Determining the Density

22. Methods for Determining the Density

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 606: Physical tests - Methods for determining the density

Standard:

EN 60811-606

Test Method:

Article 4.4

Test Equipment:

analytical balance

liquid bath

More Less
23. Method A – Immersion Method

23. Method A – Immersion Method

Title:

Plastics - Methods for determining the density of non-cellular plastics - Part 1: Immersion method, liquid pyknometer method and titration method

Standard:

EN ISO 1183-1

Test Method:

Article 5.1

Test Equipment:

analytical balance

liquid bath

More Less
24. Shore A, D

24. Shore A, D

Title:

Plastics and ebonite - Determination of indentation hardness by means of a durometer (Shore hardness)

Standard:

EN ISO 868

Test Method:

Article 8

Test Equipment:

Tester HPE II Bareiss

More Less
25. Shore A, D

25. Shore A, D

Title:

Rubber, vulcanized or thermoplastic - Determination of indentation hardness - Part 1: Durometer method (Shore hardness)

Standard:

ISO 7619-1

Test Method:

Article 7

Test Equipment:

Tester HPE II Bareiss

More Less
26. Measurement of Shore D Hardness of PE Sheath

26. Measurement of Shore D Hardness of PE Sheath

Title:

Electric cables - Additional test methods

Standard:

HD 605.S2

Test Method:

Article 2.2.1
Method A / B

Test Equipment:

Tester HPE II Bareiss

More Less
27. Determination of Tear Resistance of the Protective Sheath

27. Determination of Tear Resistance of the Protective Sheath

Title:

Electric cables - Additional test methods

Standard:

HD 605.S2

Test Method:

Article 2.2.2
Method 1/ Method 2

Test Equipment:

Tensile test machine TIRA 3kN

punch

machine for preparing test pieces

Range of Use:

max. 3 kN

More Less
28. Tensile Test on Metallic Components

28. Tensile Test on Metallic Components

Title:

Electric cables - Additional test methods

Standard:

HD 605.S2

Test Method:

Article 2.3.1

Test Equipment:

tensile test machine TIRA 3kN

tensile test machine ZD 10/90 100kN

Range of Use:

max. 100 kN

More Less
29. Resistance to water penetration

29. Resistance to water penetration

Title:

Low-frequency cables with polyolefin insulation and moisture barrier polyolefin sheath

Standard:

EN 60708

Test Method:

EN 60794

Method F5: water penatration

F5A/B

Test Equipment:

Test device according to Figure 29

Range of Use:

Diameter max. 100 mm

More Less
30. Testing of Adherence of Insulation on Messenger Conductor

30. Testing of Adherence of Insulation on Messenger Conductor

Title:

Overhead distribution cables of rated voltage U0/U (Um): 0,6/1 (1,2) kV - Part 2: Additional test methods

Standard:

HD 626.2

Test Method:

Article 2.2.2 Method 2

Test Equipment:

Tensile test machine ZD 10/90 100kN

Range of Use:

max. 100 kN

cross-section 16,25,35,50,70,95,120, 150 mm2

More Less
31. Testing of Adherence of Insulation on Conductor

31. Testing of Adherence of Insulation on Conductor

Title:

Overhead distribution cables of rated voltage U0/U (Um): 0,6/1 (1,2) kV - Part 2: Additional test methods

Standard:

HD 626.2

Test Method:

Article 2.2.3 Method 3

Test Equipment:

Tensile test machine ZD 10/90 100kN

Range of Use:

max. 100 kN

More Less
32. Testing of Adherence of Insulation on Conductor

32. Testing of Adherence of Insulation on Conductor

Title:

Overhead distribution cables of rated voltage U0/U (Um): 0,6/1 (1,2) kV - Part 2: Additional test methods

Standard:

HD 626.2

Test Method:

Article 2.2.4 Method 4

Test Equipment:

Tensile test machine ZD 10/90 100kN

Range of Use:

max. 100 kN
cross-section 35,50,70,95 mm2

More Less
33. Testing of Adherence of Insulation on Messenger Conductor

33. Testing of Adherence of Insulation on Messenger Conductor

Title:

Overhead distribution cables of rated voltage U0/U (Um): 0,6/1 (1,2) kV - Part 2: Additional test methods

Standard:

HD 626.2

Test Method:

Article 2.2.5 Method 5

Test Equipment:

Tensile test machine ZD 10/90 100kN

Range of Use:

max. 100 kN
cross-section 35,50,70,95 mm2

More Less
34. Adhesion Between Core Insulation of XLPE insulated Conductors and Cast Resin

34. Adhesion Between Core Insulation of XLPE insulated Conductors and Cast Resin

Title:

Distribution cables of rated voltage 0,6/1 kV - Section 5G: Cables with (type 5G-1) or without (type 5G-2) concentric conductor

Standard:

DIN VDE 0276-603 5G

Test Method:

Article 7

Test Equipment:

Tensile test machine TIRA 3kN

peeling device

silicon mould

Range of Use:

max. 3 kN

More Less

2. Electric Tests

35. Electrical Resistance - Conductor

35. Electrical Resistance - Conductor

Title:

Electric cables - Additional test methods

Standard:

HD 605.S2

Test Method:

Article 3.1.1

Test Equipment:

High-precision automatic inspection and test unit for electrical resistance 
200 µΩ to 20 kΩ

Range of Use:

max. 630 mm2

More Less
36. Electrical Resistance - Conductor

36. Electrical Resistance - Conductor

Title:

Conductors of insulated cables

Standard:

EN 60228

Test Method:

Annex A

Test Equipment:

High-precision automatic inspection and test unit for electrical resistance
200 µΩ to 20 kΩ

Range of Use:

max. 630 mm2

More Less
37. Electrical d.c. Resistance of Conductor

37. Electrical d.c. Resistance of Conductor

Title:

Electrical test methods for low voltage energy cables

Standard:

EN 50395

Test Method:

Article 5

Test Equipment:

High-precision automatic inspection and test unit for electrical resistance
200 µΩ to 20 kΩ

Range of Use:

max. 630 mm2

More Less
38. Electrical Resistance of Conductors

38. Electrical Resistance of Conductors

Title:

Low-frequency cables and wires with PVC insulation and PVC sheath – Part 1: General test and measuring methods (IEC 60189)

Standard:

IEC 60189

Test Method:

Article 8.1

Test Equipment:

High-precision automatic inspection and test unit for electrical resistance 
200 µΩ to 20 kΩ

Range of Use:

max. 630 mm2

More Less
39. Voltage Tests on Complete Cable

39. Voltage Tests on Complete Cable

Title:

Voltage tests on complete cable

Standard:

HD 605.S2

Test Method:

Article 3.2.1

Test Equipment:

High voltage device
max. 35 kV AC
max. 12.5 kV DC
max. 300 V DC

Range of Use:

Cables up to 1 kV

More Less
40. Voltage Tests on Cores

40. Voltage Tests on Cores

Title:

Electric cables - Additional test methods

Standard:

HD 605.S2

Test Method:

Article 3.2.2

Test Equipment:

High voltage device
max. 35 kV AC
max. 12.5 kV DC
max. 300 V DC

Range of Use:

Cables up to 1 kV

More Less
41. Voltage Tests on Oversheath

41. Voltage Tests on Oversheath

Title:

Electric cables - Additional test methods

Standard:

HD 605.S2

Test Method:

Article 3.2.3

Test Equipment:

High voltage device
max. 35 kV AC
max. 12.5 kV DC
max. 300 V DC

Range of Use:

cables up to 1 kV

More Less
42. Check for the Absence of Faults in Insulation

42. Check for the Absence of Faults in Insulation

Title:

Electrical test methods for low voltage energy cables

Standard:

EN 50395

Test Method:

Article 10

Test Equipment:

VN High voltage device
max. 35 kV AC
max. 12.5 kV DC
max. 300 V DC

Range of Use:

Cables up to 1 kV

More Less
43. Voltage Test on Completed Cable

43. Voltage Test on Completed Cable

Title:

Electrical test methods for low voltage energy cables

Standard:

EN 50395

Test Method:

Article 6

Test Equipment:

High voltage device
max. 35 kV AC
max. 12.5 kV DC
max. 300 V DC

Range of Use:

Cables up to 1 kV

More Less
44. Voltage Test on Cores in Water

44. Voltage Test on Cores in Water

Title:

Electrical test methods for low voltage energy cables

Standard:

EN 50395

Test Method:

Article 7

Test Equipment:

High voltage device
max. 35 kV AC
max. 12.5 kV DC
max. 300 V DC

Range of Use:

Cables up to 1 kV

More Less
45. Dielectric Strength

45. Dielectric Strength

Title:

Low-frequency cables and wires with PVC insulation and PVC sheath – Part 1: General test and measuring methods

Standard:

IEC 60189

Test Method:

Article 8.2

Test Equipment:

Insulation resistance tester Megger
High voltage device Hipotronic

Range of Use:

Megger max. 5kV DC
Hypotronic max. 3.75 AC

More Less
46. Insulation Resistance Test on Insulated Cores

46. Insulation Resistance Test on Insulated Cores

Title:

Electric cables - Additional test methods

Standard:

HD 605.S2

Test Method:

Article 3.3.1

Test Equipment:

Insulation resistance tester Megger

Range of Use:

Cables up to 1 kV

More Less
47. Insulation Resistance Test on Screened or Armoured Complete Cable

47. Insulation Resistance Test on Screened or Armoured Complete Cable

Title:

Electric cables - Additional test methods

Standard:

HD 605.S2

Test Method:

Article 3.3.4

Test Equipment:

Insulation resistance tester

Range of Use:

Cables up to 1 kV

More Less
48. Insulation Resistance Test on Unscreened or Unarmoured Complete Cable

48. Insulation Resistance Test on Unscreened or Unarmoured Complete Cable

Title:

Electric cables - Additional test methods

Standard:

HD 605.S2

Test Method:

Article 3.3.3

Test Equipment:

Insulation resistance tester

Range of Use:

Cables up to 1 kV

More Less
49. Oversheath Resistance Test on Screened or Armoured Complete Cable

49. Oversheath Resistance Test on Screened or Armoured Complete Cable

Title:

Electric cables - Additional test methods

Standard:

HD 605.S2

Test Method:

Article 3.3.4

Test Equipment:

Insulation resistance tester

Range of Use:

Cables up to 1 kV

More Less
50. Insulation Resistance Test

50. Insulation Resistance Test

Title:

Electrical test methods for low voltage energy cables

Standard:

EN 50395

Test Method:

Article 8

Test Equipment:

Insulation resistance tester

Range of Use:

Cables up to 1 kV

More Less
51. Insulation Resistance

51. Insulation Resistance

Title:

Low-frequency cables and wires with PVC insulation and PVC sheath – Part 1: General test and measuring methods

Standard:

IEC 60189

Test Method:

Article 3.4

Test Equipment:

Insulation resistance tester

Range of Use:

Cables up to 1 kV

More Less
52. Surface Resistance of the Cable Oversheath

52. Surface Resistance of the Cable Oversheath

Title:

Electric cables - Additional test methods

Standard:

HD 605.S2

Test Method:

Article 3.4

Test Equipment:

Insulation resistance tester 

Range of Use:

max. 5kV DC

More Less
53. Surface Resistance of Sheath

53. Surface Resistance of Sheath

Title:

Electrical test methods for low voltage energy cables

Standard:

EN 50395

Test Method:

Article 11

Test Equipment:

Insulation resistance tester

Range of Use:

max. 5kV DC

More Less
54. DC Voltage Test on Insulation

54. DC Voltage Test on Insulation

Title:

Electric cables - Additional test methods

Standard:

HD 605.S2

Test Method:

Article 3.2.2.1

Test Equipment:

High voltage device max. 12.5 kV DC

water bath

Range of Use:

max. 12.5 kV DC

More Less
55. Long Term Resistance of Insulation to d.c.

55. Long Term Resistance of Insulation to d.c.

Title:

Electrical test methods for low voltage energy cables

Standard:

EN 50395

Test Method:

Article 9

Test Equipment:

High voltage device max. 300 V DC

water bath

Range of Use:

max. 300 V DC

More Less
56. Measurement of Electrical Resistence of Conductor, Mutual Capacitance and Capacitance Unbalance

56. Measurement of Electrical Resistence of Conductor, Mutual Capacitance and Capacitance Unbalance

Title:

Low-frequency cables and wires with PVC insulation and PVC sheath – Part 1: General test and measuring methods

Standard:

IEC 60189

Test Equipment:

Automatic telephone cable tester AESA

Range of Use:

max. diameter of conductor 1.0 mm

More Less
57. Measurement of HF Parameters (up to 10 MHz)

57. Measurement of HF Parameters (up to 10 MHz)

For further information, please contact our laboratory.

More Less
58. Measurement of Reduction Factor

58. Measurement of Reduction Factor

Title:

Testing of cables, wires and flexible cords - reduction factor

Standard:

DIN VDE 57472-507 (VDE 0472-507)

Test Method:

According to standard

More Less
59. Water Absorption Tests - Electrical Procedure

59. Water Absorption Tests - Electrical Procedure

Title:

Electric and optical fibre cables - Test methods for non-metallic materials - Part 402: Miscellaneous tests - Water absorption tests

Standard:

EN 60811-402

Test Method:

Article 4.3

Test Equipment:

high voltage device

water bath

Range of Use:

Temperature max. 99°C
AC max. 35 kV
DC max. 12,5 kV

More Less

3. Tests under Fire Conditions

61. Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables - Category A F/R

61. Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables - Category A F/R

Title:

Tests on electric and optical fibre cables under fire conditions - Part 3-21: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category A F/R

Standard:

EN 60332-3-21

Test Equipment:

According to standard

More Less
62. Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables - Category A

62. Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables - Category A

Title:

Tests on electric and optical fibre cables under fire conditions - Part 3-22: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category A

Standard:

EN 60332-3-22

Test Equipment:

According to standard

More Less
63. Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables - Category B

63. Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables - Category B

Title:

Tests on electric and optical fibre cables under fire conditions - Part 3-23: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category B

Standard:

EN 60332-3-23

Test Equipment:

According to standard

More Less
64. Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables - Category C

64. Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables - Category C

Title:

Tests on electric and optical fibre cables under fire conditions - Part 3-24: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category C

Standard:

EN 60332-3-24

Test Equipment:

According to standard

Range of Use:

Also according to DIN VDE 0276-604-5G

More Less
65. Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables - Category D

65. Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables - Category D

Title:

Tests on electric and optical fibre cables under fire conditions - Part 3-25: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category D

Standard:

EN 60332-3-25

Test Equipment:

According to standard

More Less
68. Corrosivity - burning

68. Corrosivity - burning

Title:

Test on gases evolved during combustion of materials from cables
Part 1: Determination of the halogen acid gas content

Standard:

EN 60754-1

Test Equipment:

According to standard

More Less
69. Corrosivity - burning

69. Corrosivity - burning

Title:

Test on gases evolved during combustion of materials from cables
Part 2: Determination of acidity (by pH measurement) and conductivity

Standard:

EN 60754-2

Test Equipment:

According to standard

More Less
70. Circuit integrity - Cables for Use in Emergency Circuits

70. Circuit integrity - Cables for Use in Emergency Circuits

Title:

Method of test for resistance to fire of unprotected small cables for use in emergency circuits

Standard:

EN 50200

Test Equipment:

According to standard

Range of Use:

Cables up to 1 kV

More Less
71. Circuit integrity - Cables for Use in Emergency Circuits

71. Circuit integrity - Cables for Use in Emergency Circuits

Title:

Method of test for resistance to fire of larger unprotected power and control cables for use in emergency circuits

Standard:

EN 50362

Test Equipment:

According to standard

Range of Use:

Cables up to 1 kV

More Less
73. Measurement of Smoke Density

73. Measurement of Smoke Density

Title:

Measurement of smoke density of cables burning under defined conditions - Part 2: Test procedure and requirements

Standard:

EN 61034-2

Test Equipment:

According to standard

More Less
75. Circuit integrity - Cables of Rated Voltage 0,6/1kV

75. Circuit integrity - Cables of Rated Voltage 0,6/1kV

Title:

Tests for electric cables under fire conditions - Circuit integrity - Part 21: Procedures and requirements - Cables of rated voltage up to and including 0,6/1,0 kV

Standard:

IEC 60331-21

Test Equipment:

According to standard

Range of Use:

Cables up to 1 kV

More Less
76. Circuit Integrity - Electric Data Cables

76. Circuit Integrity - Electric Data Cables

Title:

Tests for electric cables under fire conditions - Circuit integrity - Part 23: Procedures and requirements - Electric data cables

Standard:

IEC 60331-23

Test Equipment:

According to standard

Range of Use:

Cables up to 1 kV

More Less
77. Heat Release and Smoke Production Measurement on Cables During Flame Spread Test

77. Heat Release and Smoke Production Measurement on Cables During Flame Spread Test

Title:

Common test methods for cables under fire conditions - Heat release and smoke production measurement on cables during flame spread test - Test Apparatus, procedures, results

Standard:

EN 50399

Test Equipment:

According to standard

Range of Use:

B2ca, Cca, Dca

More Less
79. Determination of Burning Behaviour by Oxygen Index

79. Determination of Burning Behaviour by Oxygen Index

Title:

Plastics - Determination of burning behaviour by oxygen index - Part 2: Ambient-temperature test

Standard:

EN ISO 4589-2

Test Equipment:

According to standard

Range of Use:

min. thickness 3 mm

More Less
81. Test for Vertical Flame Propagation for a Single Insulated Wire or Cable

81. Test for Vertical Flame Propagation for a Single Insulated Wire or Cable

Title:

Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1 kW pre-mixed flame

Standard:

EN 60332-1-2

Test Equipment:

According to standard

More Less
82.  Test for Vertical Flame Propagation for a Single Insulated Wire or Cable - Procedure for Determination of Flaming Droplets/Particles

82. Test for Vertical Flame Propagation for a Single Insulated Wire or Cable - Procedure for Determination of Flaming Droplets/Particles

Title:

Tests on electric and optical fibre cables under fire conditions - Part 1-3: Test for vertical flame propagation for a single insulated wire or cable - Procedure for determination of flaming droplets/particles

Standard:

EN 60332-1-3

Test Equipment:

According to standard

More Less
84. Test for Vertical Flame Propagation for a Single Insulated Wire or Cable - Procedure for Diffusion Flame

84. Test for Vertical Flame Propagation for a Single Insulated Wire or Cable - Procedure for Diffusion Flame

Title:

Tests on electric and optical fibre cables under fire conditions - Part 2-2: Test for vertical flame propagation for a single small insulated wire or cable - Procedure for diffusion flame

Standard:

EN 60332-2-2

Test Equipment:

According to standard

Range of Use:

for cables with a diameter up to 0.5 mm

More Less

We hold many product certificates and other documents proving our competencies and the highest product quality. The following links will refer you to the web pages of our prominent partners in the area of product certification, conformity evaluation, product classification and fire resistance tests.