Description |
Certificates |
EC Declaration of Conformity |
Data Sheet |
NHXMH |
Cu core, unscreened |
 As installation cable for fixed installation over, on, in and under plaster, in dry, damp and wet premises and in masonry and also in the open air but not for direct burial. Since they are free from halogens and exhibit enhanced fire performance, these cables are used in those applications where in the event of fire, the negative effects on concentrations of people and valuable material goods must be minimised.
|
VDE (DE) |
 |
Download |
PRAFlaSafe X |
Cu core, unscreened |
 This cable is intended for the stationary distribution of electrical energy in dry or damp premises. Suitable for hotels, hospitals, underground railways, airports etc. to protect people and technical building equipment in the event of fire if circuit integrity is not required. The cable releases little heat and smoke under fire. The cable is not UV-resistant.
|
EZÚ (CZ) |
 |
|
PRAFlaSafe + X |
Cu core, unscreened |
 This cable is intended for the stationary distribution of electrical energy and can be used in enviroments according to the External influences table below as long as the ends of the cable are thoroughly secured against the ingress of water and moisture and its sheath remains undamaged during installation and operation. The terminal equipment into which the cable is connected (e.g. distribution boxes, switchboards, couplers etc.) must comply with at least the same operating environment requirements as the cable itself. The cable is intended for fixed, universal installation – outside in air (the cable is not self-supporting) or underground, but also inside buildings such as hotels, hospitals, underground railways, airports and in other places where there is an increased concentration of people, etc. to protect people and technical building equipment in the event of fire if circuit integrity is required. The cable releases little heat and smoke under fire. The cable is UV-resistant.
|
EZÚ (CZ) |
 |
|
N2XH |
Cu core, unscreened |
 These cables are intended for the stationary distribution of electrical energy in dry or damp premises and for fixed installations in air or concrete. Suitable for hotels, hospitals, underground railways, airports etc. to protect people and technical building equipment in the event of fi re if circuit integrity is not required. Not allowed for installations underground or in water.
|
VDE (DE), EZÚ (CZ) |
 |
Download |
PRAFlaSafe AX |
Al core, unscreened |
 This cable is intended for the stationary distribution of electrical energy in dry or damp premises. Suitable for hotels, hospitals, underground railways, airports etc. to protect people and technical building equipment in the event of fire if circuit integrity is not required. The cable releases little heat and smoke under fire. The cable is not UV-resistant.
|
EZÚ (CZ) |
 |
|
PRAFlaSafe + AX |
Al core, unscreened |
 This cable is intended for the stationary distribution of electrical energy and can be used in enviroments according to the External influences table below as long as the ends of the cable are thoroughly secured against the ingress of water and moisture and its sheath remains undamaged during installation and operation. The terminal equipment into which the cable is connected (e.g. distribution boxes, switchboards, couplers etc.) must comply with at least the same operating environment requirements as the cable itself. The cable is intended for fixed, universal installation – outside in air (the cable is not self-supporting) or underground, but also inside buildings such as hotels, hospitals, underground railways, airports and in other places where there is an increased concentration of people, etc. to protect people and technical building equipment in the event of fire if circuit integrity is not required. The cable releases little heat and smoke under fire. The cable is UV-resistant.
|
EZÚ (CZ) |
 |
|
(N)A2XH |
Al core, unscreened |

|
on request |
 |
|
PRAFlaSafe +T |
Cu flexible core, unscreened |

|
EZÚ (CZ) |
 |
Download |
N2XCH |
Cu core, screened |
 These cables are intended for the stationary distribution of electrical energy in dry or damp premises and for fixed installations in air or concrete. Suitable for hotels, hospitals, underground railways, airports etc. to protect people and technical building equipment in the event of fi re if circuit integrity is not required. Not allowed for installations underground or in water.
|
VDE (DE), EZÚ (CZ) |
 |
Download |
PRAFlaDur |
Cu core, unscreened |
 This cable is intended for the stationary distribution of electrical energy in dry or damp premises. Suitable for hotels, hospitals, underground railways, airports etc. to protect people and technical building equipment in the event of fire if circuit integrity is required (circuit integrity is only maintained if these cables are installed with specified supporting elements). The cable releases little heat and smoke under fire. The cable is not UV-resistant.
|
EZÚ (CZ) |
 |
|
PraFlaDur + |
Cu core, unscreened |
 This cable is intended for the stationary distribution of electrical energy and can be used in enviroments according to the External influences table below as long as the ends of the cable are thoroughly secured against the ingress of water and moisture and its sheath remains undamaged during installation and operation. The terminal equipment into which the cable is connected (e.g. distribution boxes, switchboards, couplers etc.) must comply with at least the same operating environment requirements as the cable itself. The cable is intended for fixed, universal installation – outside in air (the cable is not self-supporting) or underground, but also inside buildings such as hotels, hospitals, underground railways, airports and in other places where there is an increased concentration of people, etc. to protect people and technical building equipment in the event of fire if circuit integrity is not required. The cable releases little heat and smoke under fire. The cable is UV-resistant.
|
EZÚ (CZ) |
 |
|
PRAFlaDur 90 |
Cu core, unscreened |
 Kabely jsou určeny pro pevný rozvod elektrické energie v obyčejném a vlhkém prostředí v hotelích, nemocnicích, v metru, na letištích atd., k ochraně lidí a technického vybavení budov v případě požáru tam, kde je požadavek na zachování funkčnosti celé kabelové instalace při požáru. Kabel v případě požáru uvolňuje malé množství tepla a kouře a navíc z něj neodkapávají žádné hořící částice. Funkčnost celé kabelové instalace v případě požáru je zaručena pouze při použití předepsaných nosných prvků a kabelových spojek. Kabely nejsou odolné vůči UV záření.
|
EZÚ (CZ) |
 |
|
PRAFlaDur +T |
Cu flexible core, unscreened |

|
EZÚ (CZ) |
 |
Download |
(N)HXH FE180/E30 |
Cu core, unscreened |
 These cables are intended for the stationary distribution of electrical energy in dry or damp premises and for fi xed installations in air or concrete. Suitable for hotels, hospitals, underground railways, airports etc. to protect people and technical building equipment in the event of fi re if circuit integrity is required (circuit integrity is only maintained if these cables are installed with specifi ed supporting elements). Not allowed for installations underground or in water. These cables are not UV-protected.
|
VDE (DE) |
 |
Download |
(N)HXH FE180/E90 |
Cu core, unscreened |
 These cables are intended for the stationary distribution of electrical energy in dry or damp premises and for fi xed installations in air or concrete. Suitable for hotels, hospitals, underground railways, airports etc. to protect people and technical building equipment in the event of fi re if circuit integrity is required (circuit integrity is only maintained if these cables are installed with specifi ed supporting elements). Not allowed for installations underground or in water. These cables are not UV-protected (UVprotection available on request only).
|
EZÚ (CZ) |
 |
Download |
(N)HXCH FE180/E30 |
Cu core, screened |
 These cables are intended for the stationary distribution of electrical energy in dry or damp premises and for fi xed installations in air or concrete. Suitable for hotels, hospitals, underground railways, airports etc. to protect people and technical building equipment in the event of fi re if circuit integrity is required (circuit integrity is only maintained if these cables are installed with specifi ed supporting elements). Not allowed for installations underground or in water. These cables are not UV-protected.
|
VDE (DE) |
 |
Download |
(N)HXCH FE180/E90 |
Cu core, screened |
 These cables are intended for the stationary distribution of electrical energy in dry or damp premises and for fi xed installations in air or concrete. Suitable for hotels, hospitals, underground railways, airports etc. to protect people and technical building equipment in the event of fi re if circuit integrity is required (circuit integrity is only maintained if these cables are installed with specifi ed supporting elements). Not allowed for installations underground or in water. These cables are not UV-protected.
|
VDE (DE) |
 |
Download |
PRAFlaCom F |
Cu core, screened |
 This cable is intended for the transmission of analog and digital data in premises where there is an increased risk of fire and a great concentration of people, if circuit integrity is not required. The cable releases little heat and smoke under fire. The cable is not UV-resistant.
|
EZÚ (CZ) |
 |
|
PRAFlaCom + F |
Cu core, screened |
 This cable is intended for the transmission of analog and digital data and can be used in enviroments according to the External influences table below as long as the ends of the cable are thoroughly secured against the ingress of water and moisture and its sheath remains undamaged during installation and operation. The terminal equipment into which the cable is connected (e.g. distribution boxes, switchboards, couplers etc.) must comply with at least the same operating environment requirements as the cable itself. The cable is intended for fixed, universal installation – outside in air (the cable is not self-supporting) or underground, but also inside buildings such as hotels, hospitals, underground railways, airports and in other places where there is an increased concentration of people, etc. to protect people and technical building equipment in the event of fire if circuit integrity is not required. The cable releases little heat and smoke under fire. The cable is UV-resistant.
|
EZÚ (CZ) |
 |
|
PRAFlaGuard F |
Cu core, screened |
 This cable is intended for the transmission of analog and digital data in premises where there is an increased risk of fire and a great concentration of people, if circuit integrity is required (circuit integrity is only maintained if these cables are installed with specified supporting elements). The cable releases little heat and smoke under fire. The cable is not UV-resistant.
|
EZÚ (CZ) |
 |
|
PRAFlaGuard + F |
Cu core, screened |
 This cable is intended for the transmission of analog and digital data and can be used in enviroments according to the External influences table below as long as the ends of the cable are thoroughly secured against the ingress of water and moisture and its sheath remains undamaged during installation and operation. The terminal equipment into which the cable is connected (e.g. distribution boxes, switchboards, couplers etc.) must comply with at least the same operating environment requirements as the cable itself. The cable is intended for fixed, universal installation – outside in air (the cable is not self-supporting) or underground, but also inside buildings such as hotels, hospitals, underground railways, airports and in other places where there is an increased concentration of people, etc. to protect people and technical building equipment in the event of fire if circuit integrity is required. The cable releases little heat and smoke under fire. The cable is UV-resistant.
|
EZÚ (CZ) |
 |
|
JE–H(St)H…Bd FE180/E30 |
Cu core, screened |
 Intended for the use in measurement and control systems in dry or damp premises and for fi xed installations on or under plaster. Suitable for hotels, hospitals, underground railways, airports etc. to protect people and technical building equipment in the event of fi re if circuit integrity is required (circuit integrity is only maintained if these cables are installed with specifi ed supporting elements). Not allowed for installations underground or in water. These cables are not UV-protected.
|
VDE (DE) |
 |
Download |
JE–H(St)H…Bd FE180/E90 |
Cu core, screened |
 Intended for the use in measurement and control systems in dry or damp premises and for fi xed installations on or under plaster. Suitable for hotels, hospitals, underground railways, airports etc. to protect people and technical building equipment in the event of fi re if circuit integrity is required (circuit integrity is only maintained if these cables are installed with specifi ed supporting elements). Not allowed for installations underground or in water. These cables are not UV-protected.
|
VDE (DE) |
 |
Download |
JE-H(St)H...Bd FE180/E30 RED |
Cu core, screened |

|
VDE (DE) |
 |
Download |
JE-H(St)H...Bd FE180/E90 RED |
Cu core, screened |

|
VDE (DE) |
 |
Download |
NN-CLN |
Cu core, armoured |
 Für die Verwendung in öffentlichen Gebäuden, Tunnels, technischen Räumen, wenn defi niertes Brandverhalten, Halogenfreiheit und ein Nagetierschutz gefordert sind.
|
on request |
 |
Download |
FRNC-AL-M |
Al core, unscreened |
 For fixed installation in interior premises and in the open air and for direct burial in cable ducts and conduits. Since they are free from halogens and exhbit enhanced fi re performance, these cables are used in those applications where in the event of fi re, the negative effect on concentrations of people and valuable material goods must be minimised.
|
on request |
 |
Download |
FRNC-AL-S(90) |
Al core, unscreened |
 For fixed installation in interior premises and in the open air and for direct burial in cable ducts and conduits. Since they are free from halogens and exhbit enhanced fire performance, these cables are used in those applications where in the event of fire, the negative effect on concentrations of people and valuable material goods must be minimised.
|
on request |
 |
Download |
AXQJ |
Al core, screened |
 Power distribution cables in power stations, industrial installations and switchgear, as well as in local mains. For fi xed installation in interior premises, cable ducts, in the open air.
|
on request |
 |
Download |
FRNC-AL-SCW |
Al core, screened |
 For fixed installation in interior premises and in the open air and for direct burial in cable ducts and conduits. Possible for underground installation. Since they are free from halogens and exhbit enhanced fi re performance, these cables are used in those applications where in the event of fi re, the negative effect on concentrations of people and valuable material goods must be minimised. The concentric ceander conductor can be used as PE or PEN conductor and needs not be cut when assembling branch joints.
|
on request |
 |
Download |