Products

 

Their properties are used in projects with a high concentration of persons in the case of traffic constructions

Halogen-free Wires
and Cables

Down
Halogen-free Wires and Cables

Used anywhere where it is necessary to lower fire hazard

  • VDE Type
  • CZ Type
  • Other Type
  • HALOGEN-FREE WIRES AND CABLES
  • HALOGEN-FREE ENERGY CABLES 0,6/1 kVFIRE RETARDANT
  • HALOGEN-FREE ENERGY CABLES 0,6/1 kVFIRE RETARDANT WITH CLASSIFICATION B2ca s1d1a1
  • HALOGEN-FREE ENERGY CABLES 0,6/1 kVFIRE RESISTANT
  • HALOGEN-FREE ENERGY CABLES 0,6/1 kVFIRE RESISTANT WITH CLASIFICATION B2ca s1d1a1
  • HALOGEN-FREE CABLES TELECOMMUNICATIONS/ SIGNALLING/ ELECTRONIC FIRE RETARDANT WITH CLASSIFICATION B2ca s1d1a1
  • HALOGEN-FREE CABLES TELECOMMUNICATIONS/ SIGNALLING/ ELECTRONICFIRE RESISTANT WITH CLASIFICATION B2ca s1d1a1
  • HALOGEN-FREE CABLES TELECOMMUNICATIONS/ SIGNALLING/ ELECTRONICFIRE RESISTANT


Description Certificates EC Declaration of Conformity Data Sheet
NHXMH Cu core, unscreened Description


As installation cable for fixed installation over, on, in and under plaster, in dry, damp and wet premises and in masonry and also in the open air but not for direct burial. Since they are free from halogens and exhibit enhanced fire performance, these cables are used in those applications where in the event of fire, the negative effects on concentrations of people and valuable material goods must be minimised.

VDE (DE) Download
PRAFlaSafe X Cu core, unscreened Description


This cable is intended for the stationary distribution of electrical energy in dry or damp premises. Suitable for hotels, hospitals, underground railways, airports etc. to protect people and technical building equipment in the event of fire if circuit integrity is not required. The cable releases little heat and smoke under fire. The cable is not UV-resistant.

EZÚ (CZ)  
PRAFlaSafe + X Cu core, unscreened Description


This cable is intended for the stationary distribution of electrical energy and can be used in enviroments according to the External influences table below as long as the ends of the cable are thoroughly secured against the ingress of water and moisture and its sheath remains undamaged during installation and operation. The terminal equipment into which the cable is connected (e.g. distribution boxes, switchboards, couplers etc.) must comply with at least the same operating environment requirements as the cable itself. The cable is intended for fixed, universal installation – outside in air (the cable is not self-supporting) or underground, but also inside buildings such as hotels, hospitals, underground railways, airports and in other places where there is an increased concentration of people, etc. to protect people and technical building equipment in the event of fire if circuit integrity is required. The cable releases little heat and smoke under fire. The cable is UV-resistant.

EZÚ (CZ)  
N2XH Cu core, unscreened Description


These cables are intended for the stationary distribution of electrical energy in dry or damp premises and for fixed installations in air or concrete. Suitable for hotels, hospitals, underground railways, airports etc. to protect people and technical building equipment in the event of fi re if circuit integrity is not required. Not allowed for installations underground or in water.

VDE (DE), EZÚ (CZ) Download
PRAFlaSafe AX Al core, unscreened Description


This cable is intended for the stationary distribution of electrical energy in dry or damp premises. Suitable for hotels, hospitals, underground railways, airports etc. to protect people and technical building equipment in the event of fire if circuit integrity is not required. The cable releases little heat and smoke under fire. The cable is not UV-resistant.

EZÚ (CZ)  
PRAFlaSafe + AX Al core, unscreened Description


This cable is intended for the stationary distribution of electrical energy and can be used in enviroments according to the External influences table below as long as the ends of the cable are thoroughly secured against the ingress of water and moisture and its sheath remains undamaged during installation and operation. The terminal equipment into which the cable is connected (e.g. distribution boxes, switchboards, couplers etc.) must comply with at least the same operating environment requirements as the cable itself. The cable is intended for fixed, universal installation – outside in air (the cable is not self-supporting) or underground, but also inside buildings such as hotels, hospitals, underground railways, airports and in other places where there is an increased concentration of people, etc. to protect people and technical building equipment in the event of fire if circuit integrity is not required. The cable releases little heat and smoke under fire. The cable is UV-resistant.

EZÚ (CZ)  
(N)A2XH Al core, unscreened Description


on request  
PRAFlaSafe +T Cu flexible core, unscreened Description


EZÚ (CZ) Download
N2XCH Cu core, screened Description


These cables are intended for the stationary distribution of electrical energy in dry or damp premises and for fixed installations in air or concrete. Suitable for hotels, hospitals, underground railways, airports etc. to protect people and technical building equipment in the event of fi re if circuit integrity is not required. Not allowed for installations underground or in water.

VDE (DE), EZÚ (CZ) Download
PRAFlaDur Cu core, unscreened Description


This cable is intended for the stationary distribution of electrical energy in dry or damp premises. Suitable for hotels, hospitals, underground railways, airports etc. to protect people and technical building equipment in the event of fire if circuit integrity is required (circuit integrity is only maintained if these cables are installed with specified supporting elements). The cable releases little heat and smoke under fire. The cable is not UV-resistant.

EZÚ (CZ)  
PraFlaDur + Cu core, unscreened Description


This cable is intended for the stationary distribution of electrical energy and can be used in enviroments according to the External influences table below as long as the ends of the cable are thoroughly secured against the ingress of water and moisture and its sheath remains undamaged during installation and operation. The terminal equipment into which the cable is connected (e.g. distribution boxes, switchboards, couplers etc.) must comply with at least the same operating environment requirements as the cable itself. The cable is intended for fixed, universal installation – outside in air (the cable is not self-supporting) or underground, but also inside buildings such as hotels, hospitals, underground railways, airports and in other places where there is an increased concentration of people, etc. to protect people and technical building equipment in the event of fire if circuit integrity is not required. The cable releases little heat and smoke under fire. The cable is UV-resistant.

EZÚ (CZ)  
PRAFlaDur 90 Cu core, unscreened Description


Kabely jsou určeny pro pevný rozvod elektrické energie v obyčejném a vlhkém prostředí v hotelích, nemocnicích, v metru, na letištích atd., k ochraně lidí a technického vybavení budov v případě požáru tam, kde je požadavek na zachování funkčnosti celé kabelové instalace při požáru. Kabel v případě požáru uvolňuje malé množství tepla a kouře a navíc z něj neodkapávají žádné hořící částice. Funkčnost celé kabelové instalace v případě požáru je zaručena pouze při použití předepsaných nosných prvků a kabelových spojek. Kabely nejsou odolné vůči UV záření.

EZÚ (CZ)  
PRAFlaDur +T Cu flexible core, unscreened Description


EZÚ (CZ) Download
(N)HXH FE180/E30 Cu core, unscreened Description


These cables are intended for the stationary distribution of electrical energy in dry or damp premises and for fi xed installations in air or concrete. Suitable for hotels, hospitals, underground railways, airports etc. to protect people and technical building equipment in the event of fi re if circuit integrity is required (circuit integrity is only maintained if these cables are installed with specifi ed supporting elements). Not allowed for installations underground or in water. These cables are not UV-protected.

VDE (DE) Download
(N)HXH FE180/E90 Cu core, unscreened Description


These cables are intended for the stationary distribution of electrical energy in dry or damp premises and for fi xed installations in air or concrete. Suitable for hotels, hospitals, underground railways, airports etc. to protect people and technical building equipment in the event of fi re if circuit integrity is required (circuit integrity is only maintained if these cables are installed with specifi ed supporting elements). Not allowed for installations underground or in water. These cables are not UV-protected (UVprotection available on request only).

EZÚ (CZ) Download
(N)HXCH FE180/E30 Cu core, screened Description


These cables are intended for the stationary distribution of electrical energy in dry or damp premises and for fi xed installations in air or concrete. Suitable for hotels, hospitals, underground railways, airports etc. to protect people and technical building equipment in the event of fi re if circuit integrity is required (circuit integrity is only maintained if these cables are installed with specifi ed supporting elements). Not allowed for installations underground or in water. These cables are not UV-protected.

VDE (DE) Download
(N)HXCH FE180/E90 Cu core, screened Description


These cables are intended for the stationary distribution of electrical energy in dry or damp premises and for fi xed installations in air or concrete. Suitable for hotels, hospitals, underground railways, airports etc. to protect people and technical building equipment in the event of fi re if circuit integrity is required (circuit integrity is only maintained if these cables are installed with specifi ed supporting elements). Not allowed for installations underground or in water. These cables are not UV-protected.

VDE (DE) Download
PRAFlaCom F Cu core, screened Description


This cable is intended for the transmission of analog and digital data in premises where there is an increased risk of fire and a great concentration of people, if circuit integrity is not required. The cable releases little heat and smoke under fire. The cable is not UV-resistant.

EZÚ (CZ)  
PRAFlaCom + F Cu core, screened Description


This cable is intended for the transmission of analog and digital data and can be used in enviroments according to the External influences table below as long as the ends of the cable are thoroughly secured against the ingress of water and moisture and its sheath remains undamaged during installation and operation. The terminal equipment into which the cable is connected (e.g. distribution boxes, switchboards, couplers etc.) must comply with at least the same operating environment requirements as the cable itself. The cable is intended for fixed, universal installation – outside in air (the cable is not self-supporting) or underground, but also inside buildings such as hotels, hospitals, underground railways, airports and in other places where there is an increased concentration of people, etc. to protect people and technical building equipment in the event of fire if circuit integrity is not required. The cable releases little heat and smoke under fire. The cable is UV-resistant.

EZÚ (CZ)  
PRAFlaGuard F Cu core, screened Description


This cable is intended for the transmission of analog and digital data in premises where there is an increased risk of fire and a great concentration of people, if circuit integrity is required (circuit integrity is only maintained if these cables are installed with specified supporting elements). The cable releases little heat and smoke under fire. The cable is not UV-resistant.

EZÚ (CZ)  
PRAFlaGuard + F Cu core, screened Description


This cable is intended for the transmission of analog and digital data and can be used in enviroments according to the External influences table below as long as the ends of the cable are thoroughly secured against the ingress of water and moisture and its sheath remains undamaged during installation and operation. The terminal equipment into which the cable is connected (e.g. distribution boxes, switchboards, couplers etc.) must comply with at least the same operating environment requirements as the cable itself. The cable is intended for fixed, universal installation – outside in air (the cable is not self-supporting) or underground, but also inside buildings such as hotels, hospitals, underground railways, airports and in other places where there is an increased concentration of people, etc. to protect people and technical building equipment in the event of fire if circuit integrity is required. The cable releases little heat and smoke under fire. The cable is UV-resistant.

EZÚ (CZ)  
JE–H(St)H…Bd FE180/E30 Cu core, screened Description


Intended for the use in measurement and control systems in dry or damp premises and for fi xed installations on or under plaster. Suitable for hotels, hospitals, underground railways, airports etc. to protect people and technical building equipment in the event of fi re if circuit integrity is required (circuit integrity is only maintained if these cables are installed with specifi ed supporting elements). Not allowed for installations underground or in water. These cables are not UV-protected.

VDE (DE) Download
JE–H(St)H…Bd FE180/E90 Cu core, screened Description


Intended for the use in measurement and control systems in dry or damp premises and for fi xed installations on or under plaster. Suitable for hotels, hospitals, underground railways, airports etc. to protect people and technical building equipment in the event of fi re if circuit integrity is required (circuit integrity is only maintained if these cables are installed with specifi ed supporting elements). Not allowed for installations underground or in water. These cables are not UV-protected.

VDE (DE) Download
JE-H(St)H...Bd FE180/E30 RED Cu core, screened Description


VDE (DE) Download
JE-H(St)H...Bd FE180/E90 RED Cu core, screened Description


VDE (DE) Download
NN-CLN Cu core, armoured Description


Für die Verwendung in öffentlichen Gebäuden, Tunnels, technischen Räumen, wenn defi niertes Brandverhalten, Halogenfreiheit und ein Nagetierschutz gefordert sind.

on request Download
FRNC-AL-M Al core, unscreened Description


For fixed installation in interior premises and in the open air and for direct burial in cable ducts and conduits. Since they are free from halogens and exhbit enhanced fi re performance, these cables are used in those applications where in the event of fi re, the negative effect on concentrations of people and valuable material goods must be minimised.

on request Download
FRNC-AL-S(90) Al core, unscreened Description


For fixed installation in interior premises and in the open air and for direct burial in cable ducts and conduits. Since they are free from halogens and exhbit enhanced fire performance, these cables are used in those applications where in the event of fire, the negative effect on concentrations of people and valuable material goods must be minimised.

on request Download
AXQJ Al core, screened Description


Power distribution cables in power stations, industrial installations and switchgear, as well as in local mains. For fi xed installation in interior premises, cable ducts, in the open air.

on request Download
FRNC-AL-SCW Al core, screened Description


For fixed installation in interior premises and in the open air and for direct burial in cable ducts and conduits. Possible for underground installation. Since they are free from halogens and exhbit enhanced fi re performance, these cables are used in those applications where in the event of fi re, the negative effect on concentrations of people and valuable material goods must be minimised. The concentric ceander conductor can be used as PE or PEN conductor and needs not be cut when assembling branch joints.

on request Download